Optimize Reservoir Stimulation with the DSA100HP1750
The DSA100HP1750 is a highly sophisticated instrument designed for precise measurements of contact angle, surface tension, and interfacial tension under extreme conditions. Capable of withstanding pressures up to 1750 bar and temperatures as high as 250 °C, this analyzer is pivotal in optimizing oil recovery processes by influencing the wettability of rock and the interplay between water and oil phases.
By integrating Krüss’s optical drop shape analysis expertise with EUROTECHNICA’s high-pressure application knowledge, the DSA100HP1750 stands as a beacon of innovation for the optimization of reservoir stimulation in oil recovery.
Applications and Measuring Techniques
This robust instrument finds its application in analyzing the surface tension of stimulation fluids and their interfacial tension with oil under storage conditions. It is also used to determine the wettability of reservoir rock in both air and oil-wet conditions.
Employing a variety of measuring methods including contact angle measurements on a solid surface and using a gas bubble beneath a solid surface in a liquid, as well as surface or interfacial tension evaluations employing the curvature of a drop or bubble, the DSA100HP1750 delivers unparalleled precision in its results.
Advanced Features for Reliable Analysis
Featuring a high-resolution camera and quality zoom lens, the DSA100HP1750 ensures accurate depiction of drops for precise measurement of contact angle or surface/interfacial tension. Combined with the ADVANCE software’s intelligent image evaluation algorithm, this instrument promises exact results, supporting a wide array of applications from hydraulic fracturing to enhanced oil recovery and bitumen recovery and processing.
Technical Specifications
- Syringe Dosing: manual
- Drop deposition (syringe dosing): manual
- Piston, volume: 11 mL
- Model: Camera CF04
- Connection: USB 3.0
- Resolution: 1920 × 1200 px
- Frame rate: 2300 fps
- Dark noise: 7 electrons
- Dynamic range: 73 dB
- Focus: manual
- Zoom: 7× zoom, manual
- View angle: ±4°
- Field of view: CF04: 3.9 mm × 3.9 mm to 24.7 mm × 24.7 mm
- Resolution of optics: CF04: 3.1 to 21.7 μm
- Types: high power monochromatic LED
- Wave length, dominant: 470 nm
- Field of light: 46 mm × 46 mm (D × H)
- Control: x-axis: manual (optional)
- Length: x-axis: 10 mm (optional)
- Model: High Speed Camera CF06
- Connection: USB 3.0
- Resolution: 640 × 480 px
- Frame rate: 3400 fps
- Dark noise: 10.5 electrons
- Dynamic range: 56.6 dB
- Focus: manual
- Zoom: 7× zoom, manual
- View angle: ±4°
- Field of view: CF06: 1.7 mm × 1.3 mm to 10.8 mm × 8.1 mm
- Resolution of optics: CF06: 2.5 to 17.8 μm
- Software type: ADVANCE
- Software languages: Chinese (simplified), English, French, German, Japanese, Korean, Portuguese, Russian, Spanish
- Software modules: Contact angle (recommended)Interfacial and surface tension of liquids: - pendant drop, rising drop (optional)- Contrained Sessile Drop (optional)
- Results: contact angle
- Range: 0 to 180° (software-based)
- Resolution: 0.01° (software-based)
- Accuracy: 0.1° (instrument-based)
- Models: conic sectionpolynomialcircleYoung-Laplaceheight-width
- Types: advancingrecedingstaticdynamic
- Results: contact angle
- Range: 0 to 180° (software-based)
- Resolution: 0.01° (software-based)
- Accuracy: 0.1° (instrument-based)
- Models: conic sectionpolynomialcircleYoung-Laplaceheight-width
- Types: advancingrecedingstaticdynamic
- Results: surface tensioninterfacial tension
- Range: 0.01 to 2000 mN/m (software-based)
- Resolution: 0.01 mN/m (software-based)
- Models: Young-Laplace
- Types: staticdynamic
- Maximum sample space: 25 cm³
- Maximum measuring length: 10 mm
- Footprint: 900 mm × 600 mm (W × D)
- Height: 900 mm
- Weight (without accessories): 80 kg
- Operating temperature: 10 to 40 °C
- Humidity: without condensation
- PC: USB 3.0
- Compartment: test liquids protected against light
- Needle protection shield: yes
- Camera und optics housing: yes
- Levelling: yes
- Voltage: 88 to 264 V
- Power consumption: 100 W
- Frequency: 50 to 60 Hz
- Range: -50 to 400 °C
- Resolution: 0.1 °C
- Precision: ±0.1 °C
- Accuracy: 1/3 DIN B(±0.1 °C at 0 °C to ±0.8 °C at 400 °C)
- Locations: sample stage, chamber, cuvette
- External sensor: 2 connectors (PT100)
- Type of temperature control: electrical
- Range of temperature control: 20 to 250 °C
- Flow-through thermostat: -
- Maximum pressure: 1750 bar (25 000 psi)
Documents & Downloads
Frequently Asked Questions
What applications is the DSA100HP1750 used for?
Can the DSA100HP1750 operate under high-pressure conditions?
What kind of measurements can the DSA100HP1750 conduct?
What features does the DSA100HP1750 include for reliable analysis?
What are the specifications of the camera system in the DSA100HP1750?
Is this instrument user-friendly for non-English speakers?
What are the temperature measurement and control capabilities of the DSA100HP1750?
Request a quote for Drop Shape Analyzer - DSA100HP1750 - Krüss
Fill out the form, give us a call or send an email and we will contact you as soon as possible.