The DSA30 Drop Shape Analyzer - Basic Version is a sophisticated instrument engineered for the precise measurement of static contact angle, facilitating efficient quality control in cleaning, coating, and wetting processes. Its design enables rapid swapping of solid samples and dosing liquids, streamlining the evaluation of cleaning efficacy or the perfection of coating applications. This versatile tool is further enhanced by optional accessories for high-temperature measurements and a suite of upgrade options to broaden its application spectrum.
Wide Range of Applications
Key applications include the analysis of surface wettability across various materials such as plastics, glass, ceramics, and metals. It’s instrumental in evaluating hydrophobic coatings’ performance, ensuring surface cleanliness, and conducting wetting analysis under controlled temperatures.
Advanced Measuring Capabilities
The DSA30B offers a comprehensive suite of measuring techniques, including contact angle measurement on a solid surface or through a gas bubble, analysis of surface tension, and the examination of roll-off behavior. Further capabilities extend to measuring dynamic contact angles and assessing dewetting behaviors, making it an invaluable tool for a broad array of industrial applications.
Technical Specifications
- Syringe Dosing: 1 × manual
- Liquid Needle double pressure dosing: optional
- Multi-dosing system (optional): up to 4 liquids software-controlled
- Drop deposition (syringe dosing): manual
- Syringes, volume: glass (500 μL), disposable (1 mL)
- Resolution (syringe dosing): -
- Speed (syringe dosing): -
- Model: Camera CF04
- Connection: USB 3.0
- Resolution: 1920 × 1200 px
- Frame rate: 2300 fps
- Dark noise: 7 electrons
- Dynamic range: 73 dB
- Focus: manual
- Zoom: 6.5× zoom, manual
- View angle: ±3°
- Field of view: CF04: 3.2 mm × 3.2 mm to 18.5 mm × 18.5 mm
- Resolution of optics: CF04: 2.5 to 16.2 μm
- Types: high power monochromatic LED
- Wave length, dominant: 470 nm
- Field of light: Ø 42 mm
- Control: x-axis: no (manual or software-controlled optional available)y-axis: no (manual or software-controlled optional available)z-axis: manual
- Length: x-axis: -y-axis: -z-axis: 45 mm
- Resolution: x-axis: -y-axis: -z-axis: 16 mm/turn
- Accuracy: x-axis: -y-axis: -z-axis: -
- Included in setup: optional
- Types: double
- Control: software-controlled
- Cartridge, volume: disposable (1 mL)
- Resolution: 0.1 μL
- Speed: fixed (fast jet)
- Model: 5 megapixel high speed camera CF10
- Connection: USB 3.0
- Resolution: 2592 × 2048 px
- Frame rate: 3450 fps
- Dark noise: 9.3 electrons
- Dynamic range: 60 dB
- Focus: manual
- Zoom: 6.5× zoom, manual
- View angle: ±3°
- Field of view: CF10: 7.1 mm × 5.6 mm to 49.8 mm × 39.4 mm
- Resolution of optics: CF10: 2.7 to 19.2 μm
- Types: internal tilting table
- Control: software-controlled
- Range: 0 to 90°
- Resolution: 0.01°
- Accuracy: 0.3°
- Zoom: 2× magnification, fixed
- Field of view: with CF04: 1.5 × 1.5 to 10.1 × 10.1 mm with CF10: 2.7 × 2.1 to 18.0 × 14.2 mm
- Resolution: with CF04: 1.3 to 8.4 μm with CF10: 1.0 to 7.0 μm
- Software type: ADVANCE
- Software languages: Chinese (simplified), English, French, German, Japanese, Korean, Portuguese, Russian, Spanish
- Software modules: Contact angle (recommended)Surface free energy of solids (optional)Interfacial and surface tension of liquids: - pendant drop, rising drop (optional)- Contrained Sessile Drop (optional)Adhesion Analysis (optional)Remote Control API (optional)Fiber contact angle: - Meniscus (optional)
- Results: contact angle
- Range: 0 to 180° (software-based)
- Resolution: 0.01° (software-based)
- Accuracy: 0.1° (instrument-based)
- Models: conic section polynomial circle Young-Laplace height-width
- Types: static dynamic tilting
- Results: surface free energy polar & disperse part acid & base part H-bond part
- Models: equation of state Zisman Fowkes Wu Owens-Wendt-Rabel-Kaelble Schultz-1 extended Fowkes acid-base theory
- Results: contact angle
- Range: 10 to 90° (software-based)
- Resolution: 0.01° (software-based)
- Minimum fiber diameter: 65 μm, 40 μm (with optional extender)
- Types: static dynamic advancing receding
- Results: contact angle
- Range: 0 to 180° (software-based)
- Resolution: 0.01° (software-based)
- Accuracy: 0.1° (instrument-based)
- Models: conic section polynomial circle Young-Laplace height-width
- Types: static dynamic tilting
- Results: surface tension interfacial tension
- Range: 0.01 to 2000 mN/m (software-based)
- Resolution: 0.01 mN/m (software-based)
- Models: Young-Laplace
- Types: static dynamic
- Results: surface tension
- Range: 0.01 to 2000 mN/m (software-based)
- Resolution: 0.01 mN/m (software-based)
- Models: Young-Laplace
- Maximum sample space: 320 mm × ∞ × 275 mm (W × D × H (without axes))
- Footprint: 610 mm × 250 mm (W × D)
- Height: 610 mm
- Weight (without accessories): 10 kg
- Operating temperature: 10 to 40 °C
- Humidity: without condensation
- PC: USB 3.0
- Needle protection shield: no
- Levelling: yes
- Voltage: 88 to 264 VAC
- Power consumption: 100 W
- Frequency: 50 to 60 Hz
- Range: -50 to 400 °C
- Resolution: 0.1 °C
- Precision: ±0.1 °C
- Accuracy: 1/3 DIN B (±0.1 °C at 0 °C to ±0.8 °C at 400 °C)
- Locations: sample stage chamber cuvette
- External sensor: 2 connectors (PT100)
- Equipment: Optional: - temperature-controlled sample stage - chamber - cuvette
- Type of temperature control: liquid liquid (large) Peltier electrical
- Range of temperature control: liquid: 5 to 90 °C liquid (large): -10 to 130 °C Peltier: -30 to 160 °C electrical: 50 to 400 °C
- Maximum sample space: 132 mm × 132 mm × 27 mm (W × D × H) (Large liquid chamber)
- Resolution: 0.1 °C
- Flow-through thermostat: with liquid
- Inert gas: yes
Documents & Downloads
Frequently Asked Questions
What is the DSA30 Drop Shape Analyzer - Basic Version?
What applications is the DSA30B suitable for?
What measuring capabilities does the DSA30B offer?
Can the DSA30B be upgraded?
What are the key specifications of the DSA30B?
What software compatibility does the DSA30B offer?
Is temperature measurement and control available on the DSA30B?
Request a quote for Drop Shape Analyzer - DSA30B - Krüss
Fill out the form, give us a call or send an email and we will contact you as soon as possible.