- Home
- /
- Products
- /
- Surface Chemistry
- /
- Dynamic Foam Analyzer - DFA100FSM - Krüss
Dynamic Foam Analyzer - DFA100FSM - Krüss
For targeted development of liquid foam: scientific analysis of foam structure and its change with time. Delivered and supported by Cromocol.
Get a Quote
Innovative Foam Analysis Technology
The Krüss Dynamic Foam Analyzer - DFA100FSM leverages advanced video image analysis to capture detailed bubble size and distribution metrics essential for the production of high-quality foam. This cutting-edge module enables producers to precisely shape their foam’s structure, offering insights into foam decay well before collapse, aiding in the enhancement of foam stability.
Wide Application Scope
Suitable for a diverse range of applications, including washing and cleaning foams, foams in food and personal care products, surfactant development, and flotation processes, the DFA100FSM caters to a broad spectrum of industrial needs.
Comprehensive Measuring Methods
Employing optically detected foam creation heights for analyzing foamability and stability, along with stirring cycles for assessing foam formation behavior in heavily foaming liquids, the DFA100FSM provides a thorough understanding of foam dynamics. Its advanced measurement capabilities extend to moisture and drainage behavior analysis through electrical conductivity, alongside detailed bubble size and distribution statistics.
Robust Software and Instrumentation
The integration with Krüss’s ADVANCE software simplifies operation with an intuitive user interface and powerful automation for repeat measurements. Offering a complete suite of data relating to foam height, structure, and liquid content, this analyzer represents a significant advancement in foam analysis technology.
Product Video
Technical Specifications
- Software type: ADVANCE
- Software languages: Chinese (simplified), English, French, German, Japanese, Korean, Portuguese, Russian, Spanish
- Software modules: Foam analysis (recommended), Remote Control API (optional)
- Analyzed foam characteristic: foamability and foam stability, foam structure: homogeneity, stability and aging
- Results: foam height, liquid height, total height, foam capacity, maximum foam density, expansion rate, foam half life time, drainage half life time, sample temperature, mean bubble area, bubble count per mm², standard deviation of mean bubble area, bubble size distribution, bubble count half life, Sauter mean radius, initial foam structure, final foam structure
- Min. recommended sample volume: 50 mL with 40 mm diameter column, 20 mL with 20 mm diameter column
- Footprint: 245 mm × 275 mm (W × D)
- Height: 460 mm
- Weight (without accessories): 13 kg
- Operating temperature: 15 to 30 °C
- Humidity: without condensation
- PC: 1× USB 2.0, 1× USB 3.0
- Voltage: 100 to 240 V
- Power consumption: 30 W
- Frequency: 50 to 60 Hz
- Sensor: PT100
- Range: 4 to 90 °C
- Resolution: 0.1 °C
- Precision: ±0.1 °C
- Accuracy: 1/3 DIN B (±0.1 °C at 0 °C / ±0.8 °C at 400 °C)
- Locations: inside sample liquid
- External sensor: optional
- Type of temperature control: optional: double-walled glass column
- Range of temperature control: 10 to 60 °C (additional thermostat needed)
- Glass columns: 40 mm diameter, temperature control option
- Filter plates for sparging: diameter: 30 mm
- Filter plate porosities: G1: nominal maximum pore size: 100 to 160 μm, G2: nominal maximum pore size: 40 to 100 μm, G3: nominal maximum pore size: 16 to 40 μm, G4: nominal maximum pore size: 10 to 16 μm
- Material of columns and frits: borosilicate glass (norm: ISO 4793)
- Material of sealings: silicone and FKM
- Diameter of minimum detectable bubble: 50 μm
- Mean field of view size: position 1: 285 mm2, position 2: 140 mm2, position 3: 85 mm2
- Focus: manual
- Connection: USB 3.0
- Performance: 2 fps at 1280 × 1024 px
- Types: LED
- Wave length, dominant (height detection): 469 nm (optional IR: 850 nm)
- Wave length, dominant (structure detection): 633 nm
- Material: -
- Highest sensor position: -
- Measured entity: -
- Theoretical measurement range: -
- Internal gas flow rate: 0.2 to 1 L/min
- External gas flow rate: 0.05 to 1 L/min
- Approved gases: air, nitrogen, carbon dioxide
- Approved pressure: 5 ± 0.5 bar
- Approved temperature: 4 to 90 °C
- Stirring speed: up to 8000 rpm
- Sensor resolution: 1728×1px
- Spatial resolution: 200 dpi | 0.125 mm
- Temporal resolution: 20 fps
- Scanning length: 216 mm
Documents & Downloads
Frequently Asked Questions
What is the Krüss Dynamic Foam Analyzer - DFA100FSM?
What are the key features of the DFA100FSM?
What types of measurements can the DFA100FSM perform?
What software languages does the DFA100FSM's software support?
Is temperature control available with the DFA100FSM?
Can the DFA100FSM analyze highly foaming liquids?
What is the minimum detectable bubble diameter with the DFA100FSM?
Request a quote for Dynamic Foam Analyzer - DFA100FSM - Krüss
Fill out the form, give us a call or send an email and we will contact you as soon as possible.