CO2 Incubator ICO - Next Generation - Memmert
Memmert ICO Next Generation CO2 incubator delivers condensation-free, homogeneous cell-culture conditions with 180 °C sterilisation and optional O2 control. Cromocol.
Get a Quote
Stable, Homogeneous Conditions for Sensitive Cell Cultures
The Memmert CO2 Incubator ICO (Next Generation) is designed to provide stable, homogeneous cultivation conditions for delicate cell cultures in research, development and clinical applications. Precise temperature control, active humidification and dehumidification, plus optimised airflow management, ensure condensation-free stability inside the working chamber at 37 °C and 95 % rh.
Precise Temperature and CO2 Control
The ICO holds working temperatures from 5 °C above ambient up to +50 °C with a setting accuracy of 0.1 °C, while a dual-beam CO2 sensor regulates CO2 from 0 to 20 % at +/- 0.2 % accuracy. Optional O2 control (1 to 20 %) extends the incubator to hypoxic and anaerobic workflows.
Hygiene and Sterilisation
The corrosion-resistant stainless steel inner chamber can be sterilised with a standard 60-minute program at 180 °C without removing the sensors, and an integrated HEPA filter helps keep the chamber clean between cultures.
Reliable Control and Connectivity
Thanks to the battery-buffered Control COCKPIT, the operating display, data logging and CO2 control remain fully functional even during a power failure. USB and Ethernet connections, a data logger with ten-year storage capacity, plus visual and acoustic alarms keep your cultures protected and your data accessible.
Technical Specifications
- Working temperature range: 5 °C above ambient temperature up to +50 °C
- Setting temperature range: +18 to +50 °C
- Setting accuracy temperature: 0.1 °C
- CO2 control with dual beam (NDIR) sensor
- CO2 setting range: 0 to 20 %
- Setting accuracy CO2: +/- 0.2 %
- O2 setting range: 1 to 20 %
- Setting accuracy O2: 0.1 %
- Peltier element limits relative humidity in the interior to 93 % rh +/- 2.5 %
- Setting range active humidity control: 40 to 97 % rh and rh-Off
- Setting accuracy humidity: 0.5 % rh
- Condensation-free stability at 37 °C and 95 % rh
- Standard sterilisation program: 60 minutes at 180 °C (without removing the sensors)
- Integrated HEPA filter
- Stainless steel inner chamber and housing
- ICO50: 56 litres, interior 400 x 425 x 330 mm
- ICO105: 108 litres, interior 560 x 480 x 400 mm
- ICO180: 177 litres, interior 600 x 590 x 500 mm
- ICO240: 243 litres, interior 600 x 810 x 500 mm
- Battery-buffered Control COCKPIT (operation, logging and CO2 control remain active during power failure)
- USB and Ethernet connections
- Data logger with ten-year storage capacity
- Visual and acoustic alarm
- Scope of delivery incl. works calibration certificate at +37 °C, 5 % CO2 (measuring point chamber centre)
Documents & Downloads
Frequently Asked Questions
What temperature and CO2 ranges does the Memmert ICO offer?
How does the ICO maintain condensation-free humidity?
Can the chamber be sterilised, and how?
Is O2 control available?
Which chamber sizes are available?
What happens during a power failure?
Request a quote for CO2 Incubator ICO - Next Generation - Memmert
Fill out the form, give us a call or send an email and we will contact you as soon as possible.