Product Description

The Optomet Fiber Micro Manipulator is a fiber-coupled SWIR laser Doppler vibrometer with a measurement head built for precise laser alignment. The beam direction is set by a mirror-controlled system that is operated with a joystick using a high gear ratio, which allows fine positioning of the laser onto small or hard-to-reach targets. Measurement is non-contact, using the Doppler effect to record velocity, displacement and acceleration.

A visible targeting laser at 510-530 nm marks where the measurement laser is pointing and assists alignment during setup. The measurement laser is a SWIR source at 1550 nm, which can measure dark, rough or glowing surfaces. The head can be combined with a microscope so that observation and measurement use separate, aligned optical paths. One documented use is hearing research, where the laser is aimed into the ear canal to study the vibrational behaviour of the ear and of middle ear implants during design, development, quality control, calibration and certification.

The head used is the Autofocus Pro mid-range fiber head, measuring 241 x 100.5 x 44 mm, with a removable fiber cable available in 2, 5 and 20+ m lengths and a working distance from 135 mm to 10 m. Autofocus, remote focus and manual focus are supported, and the minimum focus spot size is typically 42 µm at 135 mm.

The system covers a frequency bandwidth from DC to 25 MHz and vibrational velocities up to 30 m/s, with a 32-bit displacement dynamic range and a displacement resolution down to 50 femtometer. Signals are handled by digital Optomet UltraDSP processing. A velocity decoder is included as standard, with displacement and acceleration decoders available as options; decoders offer multiple measuring ranges and can be retrofitted or upgraded without returning the instrument to the factory.

Digital output is via Gigabit Ethernet (RJ45) or WiFi, with three standard BNC analog outputs. The unit has a 3.5” colour screen with a 20-segment LED bargraph and is operated through a touch screen, knobs with push-button, and a key switch. OptoGUI software provides remote control, data acquisition and analysis in single-point mode over the digital Ethernet connection.

Specifications

  • Fiber-coupled SWIR laser Doppler vibrometer with mirror-controlled, joystick-operated beam steering
  • Velocity, displacement and acceleration; DC to 25 MHz; up to 30 m/s
  • 1550 nm measurement laser (class 1) and 510-530 nm visible targeting laser (class 2)
  • 32-bit displacement dynamic range; displacement resolution down to 50 femtometer
  • Autofocus Pro mid-range fiber head: 135 mm to 10 m working distance, 42 µm min. spot at 135 mm
  • Removable fiber cable in 2, 5, 20+ m lengths; autofocus, remote and manual focus
  • Gigabit Ethernet (RJ45) / WiFi and 3x BNC analog outputs; digital Optomet UltraDSP processing
  • OptoGUI software for remote control, data acquisition and analysis

Technical Specifications


Manipulator & Alignment
  • Beam steering: mirror-controlled system for precise laser alignment
  • Operation: joystick with high gear ratio
  • Targeting laser: integrated visible laser for alignment
  • Microscope compatibility: can be combined with a microscope for separate, aligned measurements

Laser
  • Laser source: SWIR laser
  • Measurement laser wavelength: 1550 nm
  • Targeting laser wavelength: 510-530 nm
  • Measurement laser safety: output power < 10 mW, class 1
  • Targeting laser safety: output power < 1 mW, class 2

Measurement
  • Measured quantities: velocity, displacement, acceleration
  • Frequency bandwidth: DC to 25 MHz
  • Max. vibrational velocity: 30 m/s
  • Displacement dynamic range: 32-bit
  • Displacement resolution: down to 50 femtometer
  • Signal processing: digital (Optomet UltraDSP)

Fiber Head (Autofocus Pro mid-range)
  • Dimensions (L x W x H): 241 x 100.5 x 44 mm
  • Fiber cable: removable; lengths 2, 5, 20+ m
  • Focusing: autofocus, remote focus, manual focus
  • Working distance: 135 mm to 10 m
  • Min. focus spot size (typ.): 42 µm at 135 mm
  • Pilot laser spot: smaller spot size of the pilot laser

Outputs & Interface
  • Digital output: Gigabit Ethernet (RJ45) / WiFi
  • Analog output: 3x standard BNC outputs
  • User interface output: 3.5" colour screen + 20-segment LED bargraph
  • User interface input: touch screen, knobs with push-button, key switch (power)
  • Software: OptoGUI for remote control, data acquisition and analysis (single-point mode)

Decoders
  • Velocity decoder: standard (required); displacement and acceleration decoders optional
  • Multiple measuring ranges per decoder; retrofittable and upgradeable without factory return

General
  • Dimensions (L x W x H, excl. handle and lens): 380 x 180 x 148 mm
  • Weight: 8 kg
  • Mounting: standard tripod screw thread
  • Power supply: 110-240 V AC (50-60 Hz) or 12 V DC
  • Power consumption: 27 W
  • Operating temperature: 0 °C to 40 °C

Frequently Asked Questions

What is the Fiber Micro Manipulator and what does it do?
The Fiber Micro Manipulator is a fiber-coupled SWIR laser Doppler vibrometer with a mirror-controlled measurement head used to position and aim the laser beam onto small or hard-to-reach targets. The mirror is steered with a joystick that has a high gear ratio, allowing fine adjustment of the beam direction. It measures vibration without contact, recording velocity, displacement and acceleration.
How is the laser aligned onto the target?
Beam direction is set by a mirror-controlled system operated with a joystick. A visible targeting laser at 510-530 nm marks where the measurement laser is pointing, which assists alignment during setup. The head can also be combined with a microscope so that measurement and visual observation use separate, aligned optical paths.
What does the measurement laser specify?
The measurement laser is a SWIR laser operating at 1550 nm with an output below 10 mW (laser class 1). The separate visible targeting laser at 510-530 nm has an output below 1 mW (laser class 2). The 1550 nm source supports measurement on dark, rough or glowing surfaces.
What frequency, velocity and displacement ranges are covered?
The system covers a frequency bandwidth from DC to 25 MHz and vibrational velocities up to 30 m/s. Displacement uses a 32-bit dynamic range with a resolution down to 50 femtometer. The measured quantities are velocity, displacement and acceleration, handled by digital Optomet UltraDSP signal processing.
Which fiber head is used and what is its working distance?
It uses the Autofocus Pro mid-range fiber head (241 x 100.5 x 44 mm), which has a removable fiber cable available in 2, 5, 20+ m lengths and supports autofocus, remote focus and manual focus. Its working distance ranges from 135 mm to 10 m, with a minimum focus spot size of typically 42 µm at 135 mm.
What is the manipulator used for?
It is used where the measurement point is small, fine, or difficult to access and the beam must be aimed precisely. One documented application is hearing research, where the head is combined with a microscope to measure ear-canal and middle-ear-implant vibration during design, development, quality control, calibration and certification.

Request a quote for Fiber Micro Manipulator - Optomet

Fill out the form, give us a call or send an email and we will contact you as soon as possible.

Back to all products